Mid-Temperature Self-Regulating Heating Cable (SLMCBL)

BriskHeat Mid-Temperature Self-Regulating Heating Cable is an ideal solution for freeze protection and low temperature process maintenance up to 230°F (110°C); Suitable for extreme cold conditions as low as -22°F (-30°C). This heating cable automatically adjusts heat output based on surface temperature.

$9,75
Under the order

BriskHeat Mid-Temperature Self-Regulating Heating Cable is an ideal solution for freeze protection and low temperature process maintenance up to 230°F (110°C); Suitable for extreme cold conditions as low as -22°F (-30°C). This heating cable automatically adjusts heat output based on surface temperature.

  • No temperature controller is required.
  • If a specific process temperature is required a temperature controller is necessary.
  • Safe for indoor and outdoor use.
  • Safe to overlap heating cable for easy installation.
  • Safe to insulate.

Select the desired cable below; adding to Cart the number of feet required.

  • Maximum continuous maintenance temperature: 230°F (110°C)
  • Maximum intermittent exposure temperature: 275°F (135°C)
  • Minimum intermittent exposure temperature: -22°F (-30°C)
  • Nominal power output at 50°F (10°C): 5, 10, 15, 20 W/ft (17, 31, 45, 60 W/m)
  • Supply voltages (AC): 110-120V or 208-277V
  • Moisture, chemical, and flame resistant
  • Bus wire gauge: 16 AWG
  • Braid resistance: Tinned copper 0.0055 ohms/ft (0.0182 ohms/m)

 

Outer Layer Options:

Product Type

Description

Nominal Dimensions

Shipping Weight:

500-ft (152m) spool

Purpose

SLMCBL-B

Tinned Copper Metal Braid

0.15” x 0.45” (3.8mm x 11.4mm)

32 lb. (14.5 kg)

Ordinary applications

SLMCBL-BP

Tinned Copper Metal Braid with

Thermoplastic Elastomer Overjacket

0.23” x 0.54” (6.0mm x 13.6mm)

37 lb. (16.8 kg)

For use in wet or weak chemical environments (i.e. weak acids)

SLMCBL-BF

Tinned Copper Metal Braid with

Fluoropolymer Overjacket

0.19” x 0.49” (4.8mm x 12.4mm)

47 lb. (21.2 kg)

For use in strong chemical environments (i.e. strong acids)

Part number voltage Watts per foot (meter) Outer cover Price
SLMCBL5120B 110-120 5 W/ft (17 W/m) Tinned Copper Metal Braid $9,75
SLMCBL5120BP 110-120 5 W/ft (17 W/m) Thermoplastic Overjacket $9,83
SLMCBL5120BF 110-120 5 W/ft (17 W/m) Fluoropolymer Overjacket $11,85
SLMCBL10120B 110-120 10 W/ft (31 W/m) Tinned Copper Metal Braid $9,83
SLMCBL10120BP 110-120 10 W/ft (31 W/m) Thermoplastic Overjacket $9,94
SLMCBL10120BF 110-120 10 W/ft (31 W/m) Fluoropolymer Overjacket $11,99
SLMCBL15120B 110-120 15 W/ft (45 W/m) Tinned Copper Metal Braid $9,94
SLMCBL15120BP 110-120 15 W/ft (45 W/m) Thermoplastic Overjacket $9,99
SLMCBL15120BF 110-120 15 W/ft (45 W/m) Fluoropolymer Overjacket $12,2
SLMCBL20120B 110-120 20 W/ft (60 W/m) Tinned Copper Metal Braid $9,99
SLMCBL20120BF 110-120 20 W/ft (60 W/m) Fluoropolymer Overjacket $12,36
SLMCBL5240B 208-277 5 W/ft (17 W/m) Tinned Copper Metal Braid $9,75
SLMCBL5240BP 208-277 5 W/ft (17 W/m) Thermoplastic Overjacket $9,83
SLMCBL5240BF 208-277 5 W/ft (17 W/m) Fluoropolymer Overjacket $11,85
SLMCBL10240B 208-277 10 W/ft (31 W/m) Tinned Copper Metal Braid $9,83
SLMCBL10240BP 208-277 10 W/ft (31 W/m) Thermoplastic Overjacket $9,94
SLMCBL10240BF 208-277 10 W/ft (31 W/m) Fluoropolymer Overjacket $11,99
SLMCBL15240B 208-277 15 W/ft (45 W/m) Tinned Copper Metal Braid $9,94
SLMCBL15240BP 208-277 15 W/ft (45 W/m) Thermoplastic Overjacket $9,99
SLMCBL15240BF 208-277 15 W/ft (45 W/m) Fluoropolymer Overjacket $12,2
SLMCBL20240B 208-277 20 W/ft (60 W/m) Tinned Copper Metal Braid $9,99
SLMCBL20240BF 208-277 20 W/ft (60 W/m) Fluoropolymer Overjacket $12,36